Hygienic Package Type Air Handling Units
Our hygienic package type air handling units are designed to meet all ventilation and air conditioning needs of all spaces that are desired to be sterile, with a single unit.
Our hygienic package type air handling units are used in class 1 to class 1 air handling units, where you need high indoor air quality (IAQ) and a particle-free environment, especially in operating rooms, intensive care rooms, vaccine rooms, electronics industry, optical industry, pharmaceutical production facilities, food production facilities and chemical industry. They are produced considering the needs of the spaces classified according to the US Federal Standard 209E for 100,000, EN 150 14644-I for class 0 and class 7, and German VDI 2803-V for M1.5 and M6.5.
Our hygienic package type air handling units comply with VDI 6022-1/3, DIN 1946-4 and EN 13053 standards. The inside of the power plant has been cleared of protrusions that may cause dust accumulation and flat surfaces have been created.
According to EN 1186, it is suitable for filter leakage class F9 and housing leakage class L2. Thanks to the silicone band that cuts the contact of the inner and outer sheet walls with each other, they do not form a thermal bridge and condensation does not occur on their surfaces.
Dust accumulation is prevented with antibacterial silicone seals applied to the joints. Our plants, which have a washable inner surface, have an extremely hygienic structure.
The air flow rates of our hygienic package type air handling units are manufactured as variable according to the desired values.
Placement of filters in our hygienic package type air handling units, G3 – G4 class and ultraviolet filters, which we can classify as coarse filters according to DIN 1946-4, are placed on the suction side of the fan and immediately after the air inlet. F7 and F9 class precision bag filters, compact filters and ozone filters are placed on the discharge side of the fan after a cell with a deflector.
H13 and H14 class hepa filters are placed in the interior of the place where they serve in clean room technology, just before the blowing terminal element. They are not placed inside the hygienic package type air handling unit. The air flow rates of Alp hygienic package type air handling units are produced as variable according to the desired values.
Alperen hygienic package air handling units, which have a modular structure, are produced in the flow range of 1,500 m3/h and 25,000 m3/h for all places that need to be sterile.
Our package type hygienic air handling units;
- In the removal of the gases released during anesthesia in the operating rooms and the pollution arising from other reasons by washing with fresh air,
In the high quality filtering of the contamination elements that can be transported to the environment with fresh air before HEPA,
By controlling the supply and intake air, keeping the space at positive pressure and thus preventing the contamination that may arise from the side volumes.
In the prevention of microbial transitions to the adjacent spaces by keeping the septic spaces at negative pressure.
In providing the temperature and humidity values of the space with certain sensitivities.
While doing all these, they are the devices used to provide economy in terms of operating costs at the same time.
Hygienic Package Type Air Handling Unit Selection Program
The selection of Alp hygienic package type air handling units is made by prioritizing low operating costs, efficiency and performance. Within the scope of this planning, equipment that provides high energy saving, durable, long-lasting, and trouble-free operation is used in the selection of hygienic package type air handling units. With the automation systems offered as options, the quality has been maximized.
ALPAIRCOMFORT, the selection software of Alp hygienic package type air handling units, enables the selection of air handling units and designing all kinds of applications on a Windows basis. With the ALPAIRCOMFORT hygienic package type air handling unit selection program developed by our experienced software engineers, it is extremely safe to choose the hygienic package type air handling unit you need.
ALPAIRCOMFORT hygienic package type air handling unit design program has been developed to select and design the ideal hygienic air handling unit. The program has many superior features such as psychometric diagram, fan selection, heat recovery selection, electric motor selection, battery selection, heat exchanger selection, filter selection, battery selection, low noise level, energy saving, printouts in pdf format.
Manufacturing Process of Hygienic Package Type Air Handling Units
Alp hygienic package type air handling units are designed to start production with the cooperation of R&D and production departments after selection from the ALPAIRCOMFORT program based on your needs. The production of hygienic package type air handling units is carried out on CNC benches, which are fully computer-aided, enabling precise and fast production. Alp hygienic package type air handling units are controlled and tested in accordance with the quality plan of the relevant product during the production and assembly stages. In this way, the performance of hygienic package type air handling units can be monitored continuously and their compliance with the relevant standards can be guaranteed. Hygienic package type air handling units, which are manufactured in the factory and passed the necessary inspections and tests, are shipped to the assembly site based on all kinds of safe transportation criteria.
It will be sufficient for you to contact our company in order to meet all your technical and commercial demands regarding our hygienic package type air handling units.
Photos of Hygienic Package Type Air Handling Units;